Exchange Your Commercial Cartridge

Video: Commercial Cartridge Exchange #

For the CCW300A, CCW300 & CCW500 AOP Systems


Instructions: Commercial Cartridge Exchange
#

For the CCW300A, CCW300 & CCW500 AOP Systems

The Cartridge must be replaced annually. No other maintenance is required.  Never attempt to service unit while it is wet.

  1. Turn OFF power to Clear Comfort system by toggling red power button to the OFF position.
  2. Turn OFF and disconnect power to Clear Comfort system from power source.
  3. Disconnect 1⁄4” blue tubing connections to cartridges.
  4. Disconnect yellow electrical power connections.
  5. Using a small flathead screwdriver, carefully release all black brackets arms.
  6. Firmly remove cartridge from black bracket housing.
  7. Replace old cartridges with new cartridges. Ensure each cartridge is properly seated in both black brackets.
  8. Secure both black cartridge bracket arms – it should easily click when secure.
  9. Reconnect blue tubing to each cartridge, ensuring proper and secure fitting.
  10. Using an airflow meter, adjust ball valve to properly size airflow through the venturi for the following ranges in the Operating Instructions section.
  11. Close the front door of the Clear Comfort system, turn latch lock to the closed position, and toggle red power button to the ON position. LED will illuminate.