View Categories

Commercial Ongoing Maintenance

2 min read

1. Cartridge Exchange(s) #

Frequency: Annually | Takes 15 Minutes

  • Remove and replace Cartridge(s)
  • Record install date on Cartridge label
  • Replace included Air Check Valves (required for warranty)
  • Confirm Air Check Valve arrow points toward plumbing
  • Use included packaging & label to return old Cartridge for recycling

2. Check Valves, Diffusers & Air Tubing #

Frequency: Monthly | Takes 5 Minutes

  • Inspect Diffusers (rod or disc) for fouling or backpressure
  • Inspect Air Tubing and Fittings for:
    • Kinks, cracks or leaks
    • Air or water leaks
    • Secure connections
  • Tighten or replace any worn or loose connections

Note: Surge pit installations require a check valve to prevent backflow into the AOP system.

3. Air Flow Setting #

Frequency: Monthly | Takes 5 Minutes

  • Confirm Air Flow Meter is clean & unobstructed
  • Verify LPM matches model specifications:
    • CCW300A: 12–14 LPM
    • CCW300: 23–28 LPM
    • CCW500: 40–55 LPM
  • Adjust as needed to maintain proper gas-to-water ratio

4. LED Indicator Lights #

Frequency: Weekly | Takes 1 Minute

  • Confirm all LEDs illuminate during startup & operation

CCW300A*, CCW300 & CCW500 Lights:

  • Red LED: System ON (System Power Switch)
  • Blue LED: Cartridge(s) functioning (Cartridge A LED and Cartridge B LED)
    • Note: CCW300A has one Blue LED light.

5. Flow Switch Inspection #

Frequency: Quarterly | Takes 5 Minutes

(If Applicable) For Diffuser Rod Installation Kits:

  • Verify system activates & deactivates with pump
  • Inspect paddle for free movement
  • Check for debris or calcium buildup
  • Replace switch if operation is inconsistent

6. Air Compressor Inspection #

Frequency: Quarterly | Takes 5 Minutes

  • Inspect & clean Air Compressor intake filter monthly or as needed
  • Clean intake and exhaust grilles as needed; remove pleated filters (if present) to improve airflow
  • Install service kit every 18 months
  • Replace Compressor after three service kits (~4.5 years)
  • Record service & replacement dates

7. Diffuser Maintenance #

Frequency: Annually | Takes 10 Minutes

  • Remove and inspect diffusers for fouling, scaling or buildup
  • Clean with muriatic acid solution (if needed) or replace if airflow is restricted
  • Confirm proper airflow & bubble distribution


8. Annual Maintenance Record #

Frequency: After Service | Takes 5 Minutes

  • Record dates and notes for all completed maintenance
  • Maintain access to system manuals & service guides

 

Powered by BetterDocs