Dealer Portal Login
Formerly Silver Bullet Water Treatment Company is now a part of Clear Comfort.
Silver Bullet Water Treatment Company is now a part of Clear Comfort.

How to Install Your Manifold Kit

Video: Manifold Install Kit  #


Full Diagram: Manifold Install Kit
#

NOTE: The Manifold injection is the preferred Clear Comfort pool and inground spa system installation method. 

Instructions: Manifold Install Kit  #

PLEASE NOTE: Turn main pool pump OFF and switch off main circuit breaker.

1. Pick Location #
  • Select a location to install Manifold, see Step 2 for proper water flow configuration position.
  • If retrofitting, cut a 11” length of the main return piping where the bypass will be installed.
    • PLEASE NOTE: The Manifold needs 1.5″ of pipe on each side for glue.
2. Select Orientation #
  • The Gate Valve Manifold can be installed either left-to-right or right-to-left to match your water flow configurations.
  • Simply align the Gate Valve Manifold’s directional flow arrows with the direction of water flow.
3. Connect to Pool Plumbing #
  • Install the Gate Valve Manifold into the 11” cut section of pool plumbing, using an appropriate PVC primer and cement.

 

4. Connect to System & Set Gate Valve Air Flow #
    • Connect blue Air Tubing from the Clear Comfort System’s L-barbed connector to the Manifold’s Venturi. IMPORTANT: The Air Tubing Air Check Valve’s arrow should point away from the Clear Comfort system and to Manifold’s Venturi.
    • Install the Valved Flowmeter Kit. For instructions, click here.
    • Turn on circulation pump and adjust the Gate Valve Manifold’s knob until the Flowmeter meets the required flow rate*.
    • If needed, use the Flowmeter’s knob for fine tuning.
    • * Required system flow rates:
      • CCW100: 5-7 LPM 
      • CCW50: 3-5 LPM

Video: Adjust Air Flow to CCW100 & CCW50 #

What are your feelings?
Updated on November 9, 2023